With high definition radiography you can achieve crisp, sharp, detailed results every time, regardless, of film speed or digital exposure times. HDX offers both high contrast for caries detection, and broad grayscale to meet the demands of variable tissue diagnosis.
Here's why the HDX should be your next X-ray;
Reduced Exposure Times
Power-packed Constant Potential (DC technology) reduces exposure times. In fact, this important innovation... “can reduce entrance exposure by up to 30%.”
Simple, Intuitive Operator Controls
- Design makes advanced technology simple to understand.
- Fully adjustable, easy to read exposure settings (.01 - 2.0).
- Remembers your most frequently used exposure settings.
- Controls can be remote-mounted or integrated.
- self-diagnostic software with audible and visual prompts
Self-Diagnostics
- Guarantees performance every time you turn the unit on.
- Error messages, both audible and visual, are clear and pinpoint the suggested operator response.
Suspension Arm
- The horizontal reach of the standard armwill easily accommodate a two-operatory pass-through design.
- Where space is limited, a short arm version is also available.
- The lightweight tubehead and stable suspension arm provide easy, accurate positioning.
Line Voltage Compensation
- Provides trouble-free operation over a wide range of image-softening voltage fluctuations.
Fast-Track Installation
- Can be quickly mounted to meet room configurations.
- Small mounting plate for pass-through installations.
Customize HDX to your practice!
- All mounted units are available with a 58” or 74” reach.
- All models are available with integrated or remote-mounted control (includes 35ft. connecting cable).
- Standard 8” round cone. Options include; 12” round, 8” & 12” rectangular.
- Mobile and portable units are available.
Best warranty in the business
Flow X-ray's HDX Intraoral X-ray is sold and warranteed exclusively through authorized Flow X-ray full service dealers, and comes with a limited two year warranty.
Technical Specifications for EnVisionDC & HDX Models
|
|
|
Technical Specifications for EnvisionDC & HDX Models
Rated Peak Tube Potential 65 kVDC
Rated Tube Current 7mA
Line Voltage Range 100-130/200-250 50/60 Hz
Line Voltage Regulation 4%
Rated Line Current 11/5.5 Amps
Exposure Time Range 0.01 to 2.00 seconds in
0.01 second increments
Accuracy ± 0.01 second
Focal Spot 0.8 x 0.8 mm
Duty Cycle 1:60 (one - 0.25 second
exposure every 15 seconds)
Total Minimum Filtration: 1.5 mm aluminum equivalent
Stock Numbers
X-ray unit 120V with 16” mounting plate
|